Lancom Systems 1711 Manuel d'utilisateur Page 73

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 82
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 72
LANCOM 821 ADSL/ISDN – LANCOM 1621 ADSL/ISDN – LANCOM 1711 VPN
Chapter 9: Troubleshooting
73
EN
tested (e.g. “DSL1” or “LAN-1”). Pay attention to the correct spelling of the
interfaces. Start the test for the specified interface by clicking on Execute.
Change then to menu item Expert configuration Status LAN statis-
tics Cable test results. The results of the cable test for the individual
interfaces are show up in a list.
The following results can occur:
OK: Cable plugged in correctly, line ok.
open with distance “0m”: No cable plugged in or interruption within less
than 10 meters distance.
open with indication of distance: Cable is plugged in, but defect (short-
circuited) at the indicated distance.
Impedance error: The pair of cables is not terminated with the correct
impedance at the other end.
Vue de la page 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 81 82

Commentaires sur ces manuels

Pas de commentaire